Drager Evita 4 Ventilator
Drager Evita 4 Ventilator
The Dräger Evita 4 Ventilator is recognized for its high-performance ventilation capabilities, providing essential support in treating severe respiratory disorders across patient populations from neonates to adults, thus making it a pivotal piece of equipment in critical care settings.
Questions About This Product?
Our representatives are waiting to answer any questions you may have.
Features:
The Dräger Evita 4 is a sophisticated ventilator designed for use in intensive care for adult, pediatric, and neonatal patients. Known for its reliability and comprehensive ventilation capabilities, the Evita 4 offers a versatile solution to a range of respiratory conditions requiring advanced respiratory support. This ventilator is widely used across various clinical settings, including intensive care units, due to its robust performance and adaptability.
Key Features of the Dräger Evita 4 Ventilator
- Advanced Ventilation Modes: The Evita 4 supports multiple ventilation modes such as Volume Control (VC), Pressure Control (PC), Synchronized Intermittent Mandatory Ventilation (SIMV), and Pressure Support Ventilation (PSV), along with other specialized modes tailored for more complex respiratory needs.
- Integrated Monitoring: Features comprehensive monitoring capabilities that allow clinicians to track vital respiratory parameters, including tidal volume, respiratory rate, and peak inspiratory pressure. This helps in making precise adjustments to ventilation based on real-time patient data.
- Neonatal Ventilation Support: Specifically includes features that cater to the sensitive needs of neonatal patients, offering gentle ventilation with accurate control.
- User-Friendly Interface: Equipped with an intuitive user interface and a large display screen, which simplifies the operation and quick access to settings and patient information.
- Safety Alarms: Comprehensive alarm systems are integrated to alert healthcare providers to potential issues, ensuring high levels of patient safety during use.
- Oxygen Therapy and Mixing: Capable of high precision oxygen delivery and mixing, ensuring optimal oxygenation levels are maintained according to patient requirements.
Applications in Medical Care
- Intensive Care Units (ICUs): The Evita 4 is ideally suited for ICUs, where patients require meticulous and continuous respiratory support. It is robust enough to handle complex cases involving critical respiratory conditions.
- Neonatal Intensive Care Units (NICUs): Its ability to provide tailored ventilation for neonates makes it an essential tool in NICUs.
- Long-Term Acute Care: The ventilator can also be used in long-term care facilities, where patients may need prolonged ventilatory support.
Specifications
Dimensions
- Height: 11.4 inches (29 cm)
- Width: 20.9 inches (53 cm)
- Depth: 17.7 inches (45 cm)
- Weight: 60 lb (27 kg)
Display
- Type: Color TFT Color Display
- Size: 6.5″ (diagonal)
Ventilation Modes
- CMV (Continuous Mandatory)
- SIMV (Synchronized Intermittent Mandatory Ventilation)
- MMV (Mandatory Minute Volume Ventilation)
- CPAP (Continuous Positive Airway Pressure)
- PS (Pressure Support)
- PCV+ (Pressure-Controlled Ventilation plus)
- Airway Pressure Release Ventilation)
Special Modes
- Apnea Ventilation
- ILV (Independent Lung Ventilation)
Measured Values Displayed
- Airway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
- Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
- Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTASB (VTPS) (0 to 3999 mL)
- Breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)
- O2 concentration: (FiO2) Inspired O2 concentration (15 to 100 Vol.%)
- Lung mechanics:
- Resistance ((0.0 to 600 mbar/L/s)(cmH2O/L/s)
- Compliance ((0.0 to 300 mL/mbar)(mL/cmH2O)
- Breathing gas temperature: 18°to 51°C
- Waveforms: Airway pressure-time, flow-time, volume-time, …
- Trends (optional): FiO2, MV, VT, f, PEEPi, R, C, etCO2, …
- Loops (optional): Paw-V, V-Flow, Flow-Paw, …
- Capnography (etCO2) (optional): 0 to 100 mmHg
- CO2 production (VCO2): 0 to 999 mL/min, STPD
- Serial dead space Vds: 0 to 999 mL, BTPS
- Dead space ventilation (Vds/VT): 0 to 99%
- O2 saturation: SpO2, pulse
User Interface
- Instructions: Detailed voice prompts and visual icons guide the responder through the use of the defibrillator
- CPR coaching: Voice coaching for adult and infant/child CPR provides instructions and audio cues for the appropriate number, rate, and depth of chest compressions, as well as for each breath
- Controls: Green On/Off button, blue i-button, orange Shock button, optional Infant/Child key
- Indicators: Ready light, blue i-button, caution light, illuminated pads, icons, Shock button lights up when a shock is advised
Date Recording and Transmission
- Infrared: Wireless transmission of event data to a Smartphone or PC, using the IrDA protocol
- HeartStart Event Review Data management software (optional) for download and review of Software: data retrieved through defibrillator’s infrared data port
- Data stored: First 15 minutes of ECG and the entire incident’s events and analysis decisions
Specifications:
| Specification | Value |
|---|---|
| Height | 11.4 inches (29 cm) |
| Width | 20.9 inches (53 cm) |
| Depth | 17.7 inches (45 cm) |
| Weight | 60 lb (27 kg) |